• Navigation überspringen
  • Zur Navigation
  • Zum Seitenende
Organisationsmenü öffnen Organisationsmenü schließen
Institute of Medical Biotechnology
  • FAUZur zentralen FAU Website
  1. Friedrich-Alexander-Universität
  2. Technische Fakultät
  3. Department Chemie- und Bioingenieurwesen
Suche öffnen
  • Campo
  • StudOn
  • FAUdir
  • Stellenangebote
  • Lageplan
  • Hilfe im Notfall
  1. Friedrich-Alexander-Universität
  2. Technische Fakultät
  3. Department Chemie- und Bioingenieurwesen

Institute of Medical Biotechnology

Menu Menu schließen
  • About Us
    • Staff
    • Open Positions
    • Our Labs
    • Contact
    Portal About Us
  • Research
    • Research Groups
    • Collaborations
    • Publications
    Portal Research
  • Teaching
    • Lectures
    • Scientific Talks
    • Safety Inductions
    Portal Teaching
  1. Startseite
  2. Research
  3. Research Groups
  4. Optical Technologies in Life Sciences
  5. PiezoGRIN: Multiphoton Imaging under high Pressures

PiezoGRIN: Multiphoton Imaging under high Pressures

Bereichsnavigation: Research
  • Research Groups
    • Muscle Opto-Biomechatronics
    • Tissue Engineering
    • Bioreactors in Tissue Engineering
    • Optical Technologies in Life Sciences
      • Label-free Multiphoton Imaging
      • Multiphoton Endomicroscopy for Life Science and Medicine
      • Raman Spectroscopy of Biological Tissue
      • PiezoGRIN: Multiphoton Imaging under high Pressures
    • High-throughput Biology & Robophotonics
  • Collaborations
  • Publications

PiezoGRIN: Multiphoton Imaging under high Pressures

Group Leaders

Oliver Friedrich

Prof. Dr. Oliver Friedrich

Head of Institute

Medical Biotechnology
Lehrstuhl für Medizinische Biotechnologie (MBT)

Raum: Room 02.024
Paul-Gordan-Str. 3
91052 Erlangen
Germany
  • Telefon: +49913185-23174-69653
  • E-Mail: oliver.friedrich@fau.de
  • Webseite: https://www.mbt.tf.fau.de
Sebastian Schürmann

PD Dr. Sebastian Schürmann, Akad. Rat

Group Leader

Medical Biotechnology
Optical Technologies in Life Sciences

Raum: Room 02.042
Paul-Gordan-Str. 3
91052 Erlangen
Germany
  • Telefon: +49913185-23311
  • E-Mail: sebastian.schuermann@fau.de
  • Webseite: https://www.mbt.tf.fau.de/
  • Label-free Multiphoton Imaging
  • Advanced Endomicroscopy for Life Science and Medicine
  • Raman Spectroscopy of Biological Tissue
  • PiezoGRIN: Multiphoton Imaging under high Pressures

PiezoGRIN – a Window to High Pressure Biotechnology

High pressure (HP) represents an environmental variable that attracts increasing interest in Biotechnology in terms of HP manipulation of biological processes to even HP sterilization of food. Likewise, HP affects many bio-ecosystems exposed to high ambient pressures, for instance in marine biotechnology. In order to study biosystems under elevated high pressures, sealing of recording and actuation metrologies against ambient atmospheric pressures is cumbersome and has limited the general availability of HP-technologies to study living cells and tissues. Optical, contact-free, assessment of cellular reactions under defined HP is an elegant method to bring together high hydrostatic pressure environments and readout technologies developed for atmospheric pressure conditions by separating both with optical windows that need to be designed to withstand HP forces. We recently engineered an optical pressure vessel, PiezoGRIN with the innovative aspect to incorporate tube-GRIN lenses to focus multiphoton excitation beams from an external objective into the chamber reservois containing living cells and tissue samples. This way, the GRIN lens can serve two purposes, acting as an optical element and serving as a HP barrier at the same time. The vessel is mountable to existing two-photon microscopes and is connected to an external pressure generator to create HP environments up to several hundred MPa (currently tested for 200 MPa). With this technology, we study label-free SHG signals originating from cells and tissues (e.g. skeletal muscle) under high hydrostatic pressures. Of particular interest is to delineate principal pressure limits for the pressure-induced irreversible muscle contracture (Friedrich et al. 2006; Schneidereit et al. 2018).PiezoGRIN optical pressure vessel in its open stainless steel components (A) and the closed sealed vessel (B). C, side view schematics showing the symmetric GRIN lens configuration in relation to the excitation objective from below for two-photon (2p) excitation and the collection condenser lens from above. Magnifications of the sample chamber environment (E-G) show the pressure force distribution lines within the chamber connected to the external pressure hose and generator (D). (H), side view of the cut-open lower hull of the vessel depicting the fitting for the GRIN lens basin (upper inlet) and the large angle drilled hull opening to enable immersion objective optical connectivity using high NA lenses from below. PiezoGRIN optical chamber in action showing muscle single fiber and whole tissue morphology at hydrostatic pressure. K, illustration of extraction of murine musculi interossei (IO) and extensor digitorum longus (edl, EDL) as well as fixing of edl single fibers. I, immersed IO tissue in open chamber with background light coming through the lens in the center and discernible copper seal in the image perimeter. J, Bright field image of IO tissue in closed chamber showing muscle fibers and blood vessels in a field of view of 0.5 mm. L, 3D image stack (115x115x43 µm) of unstained fixed EDL single fiber pressurized at 200 MPa, obtained by recording transmitted SHG signal of 2p-excitation. M, cropped slice from within stack (L) is showing SHG signal of A-bands of the intracellular sarcomere structures from myofibrils. M, time-lapse (mm:ss) SHG images of live IO muscle in calcium free internal solution contracting after compression to 30 MPa. The compression phase concludes at t = 1 min, contracture of the fiber occurs just before the 2 minute mark (Schneidereit et al. 2018).

References:

  • Schneidereit S, Schürmann S, Friedrich O (2018) PiezoGRIN: A High-Pressure Chamber Incorporating GRIN Lenses for High-Resolution 3D-Microscopy of living Cells and Tissues. Adv Sci. 6(4):1801453. doi: 10.1002/advs.201801453.
  • Friedrich O, Wegner FV, Hartmann M, Frey B,et al. (2006)  ‚In situ‘ high pressure confocal Ca(2+)-fluorescence microscopy in skeletal muscle: a new method to study pressure limits in mammalian cells. Undersea Hyperb Med. 33(3):181-95.

Weitere Hinweise zum Webauftritt

Studying Life Science Engineering…

Macrophages in the Sky? This is the sensational title of the LSE promo video, meant to fuel your imagination and curiosity about this field of study. If it did not fail doing so, feed yourself more information by watching „why study LSE“ and „what is LSE“, adjacent to the trailer.

Macrophages in the Sky?

https://www.mbt.tf.fau.de/files/2019/12/Fresszellen-über-Erlangen-Life-Science-Engineering-studieren-in-Erlangen.mp4

Why study LSE?

https://www.mbt.tf.fau.de/files/2019/12/Warum-solltest-Du-Life-Science-Engineering-studieren-.mp4

What is LSE?

https://www.mbt.tf.fau.de/files/2019/12/Was-ist-Life-Science-Engineering-.mp4
Friedrich-Alexander-Universität
Erlangen-Nürnberg

Schlossplatz 4
91054 Erlangen
  • Imprint
  • Privacy
  • Accessibility
  • Facebook
  • RSS Feed
  • Twitter
  • Xing
Nach oben